Categories

Newsletter

Raypak Digital ASME low NOx, commercial ASME heater 400,000 btu, Natural gas

RayPak Digital Commercial ASME Heater 407,000 BTU Natural Gas
Click to enlarge
Price: $2,159.00
Product ID : C-R407A-EN-C

Purchase

Description

RayPak Digital Low NOx Commercial ASME Heater 400,000 BTU Natural Gas - c-r407a-en-c


Texas ASME Pool heater compliance kit Flow switch and Temperature /Pressure gauge

Required for commercial/public pool heater installations in Texas

Kit Contents includes:
-----------------------------
(1) Temperature and Pressure gauge
(1) Pre-wired Flow Switch with outdoor cover
(2) Paddles
(1) Screw, #6-32 x 3/16
(1) 2” CPVC Tailpiece Connector
(1) 2” CPVC Manifold Adapter
(1) O-Ring
(2) Female spade terminals
(1) Ring nut


RayPak Pool/Spa Heater Features

Digital Control
Microprocessor-controlled Thermostat
The Raypak Digital gas heater is equipped with a microprocessor-based control center. This control allows you to set your pool or spa temprature precisely at your preferred setting just by pressing an up or down temprature control button. The digital display gives you a constant readout of your water temperature.
Raypak Digital gas heater

Self-Diagnostic Remote-Compatible
Troubleshooting a Raypak gas heater has never been easier. The Raypak Digital has on-board diagnostic controls that let the user and the service professional know what is going on with the heater at all times. In the unlikely event that a problem developes, the digital display easily points out the problem and the probable cause. It's like having a service technician built into every Raypak Digital heater. The Raypak Digital is compatible with most major brand pool control and remote systems on the market today. Any two- or three-wire remote can connect to the Raypak Digital heater and be integrated into the pool control system of your choice.
Heat Exchanger
Condensation-Free Operation
Both water temperature and flow rate inside the heater are controlled to help eliminate condensation, sooting and scale buildup that cab shorten the life of a heater. Raypak engineered the Unitherm Govenor Specifically for pool heater application, regulating low-temperature incoming water to help reduce condensation. For over 30 years, Raypak has led the industry, setting the standard for condensation protection.
Raypak Digital Low NOx heater Condensation-Free heat exchanger
Rust-Free Waterways
The Raypak Digital, with polymer headers, is equipped with an integral copper finned-tube heat exchanger and stainless steel tube sheets. This unique construction guarantees rust-free operation, especially important when heating spas and smaller pools. Even the smallest details such as the studs and nuts are made out of stainless steel. the Payoff? A heater that will last years after yearsand can easily be services if the need should ever arise.
Raypak Digital, with polymer headers is equipped with an integral copper finned-tube heat exchanger
Burners
Stailess Steel Burners
Burner design is a critical component in any gas heater. The stailess steel burner system used in the Raypak Digital is inherently forgiving and extremely robust. The burner is self-adjusting to compensate for gas pressure fluctuations, allowing the heater to always burn clean and safe.
Raypak Digital is inherently forgiving and extremely robust The burner is self-adjusting to compensate for gas pressure fluctuations allowing the heater to always burn clean and safe
Fan-Assisted Combustion Pilot Ignition
Not all low NOx heaters are made the same. The Raypak Low NOx design uses a fan to provide cool, controlled combustion air to the burners. Other brands use a fan to pull hot flue gases through the heater. The RAypak design allows the heater to outperform all others during cold starts and provide longer components life. The Raypak Digital use a spark-to-pilot ignition system. This is the most reliable and robust ignition system available, an industry-proven standard for over 20 years.
Copper Fin Tube - (Standard)
The Raypak Digital is built with the highest quality integral copper fin tube available. Copper is well known for it's ability to efficiently transfer heat, and is an excellent choice for pool and spa heater exchangers, where the water chemistry is properly maintained.
Raypak Digital is built with the highest quality integral copper fin tube available.
ASME Copper Fin tube - (Optional)
The Raypak Digital ASME gas heater is equipped with .062" wall integral copper finned tubes. This tubing is approximately 50% larger in wall thickness than standard tubing, providing additional resistance to wear from chemical corrosion. The Raypak Digital heater is also available in an optional ASME version. Raypak has inspectors on-site daily performing certifications for our pool heater and commercial boiler production that may require ASME. Being in the boiler business for over 50 yearstruly ,akes Raypak the leader for your commercial needs. Why ASME? Most local codes require that public pools, pools that are in condominiums, appartments, or other commercial applications, be ASME certified. ASME stands for American Society of Mechanical Engineers, a non-profit group which sets many industrial and manufacturing standards. A pool heater that is made to ASME standard must perform to a set of specifications as determined by ASME, specifically in relation to the operating water pressure the application can handle. Each and every ASME heat exchanger that goes into RAypak heater is certified by a state inspector to make sure it complies with ASME codes for pool heaters.
Raypak Digital ASME gas heater is equipped with .062
Raypak has inspectors on-site daily performing certifications for our pool heater and commercial boiler production that may require ASME.
Glass-Lined Cast Iron Headers
Raypak has applied it's years of commercial boiler experience to the design of the cast iron glass-lined header. A metal header design allows for the higher working pressures required by ASME. Only after the material meets the stress anaysis and metal composition tests is it approved for use in an ASME unit
Raypak has applied it's years of commercial boiler experience to the design of the cast iron glass-lined header.
Cupro-Nickel Fin Tube - (Optional)
Raypak heaters are available with an optional cupro-nickel fin tube heat exchanger for added protection against aggressive water chemistry, which has been known to attack copper heat exchangers and cause premature failure. Cupro-nickel offers superior tolerance to bad water chemistry and increases erosion protection, thanks to a harder surface and wall that is approximately 50% thicker than our standard copper fin tube. When you're unsure of your ability to maintain the pool or spa water chemistry, a cupro-nickel heat exchanger is a cost-effective way to protect against premature failure.
Raypak heaters are available with an optional cupro-nickel fin tube heat exchanger for added protection against aggressive water chemistry.

Raypak Low NOx heater:

Designed to meet low Nitrogen Oxide (NOx) standards for pool heater and boilers. The Raypak Low NOx heaters are mostly used in Southern California and Texas and any other areas applying the stringent SCAQMD standard. All digital control unit with high thermal efficiency, and Polymer headers for years of rust-free operation.

Raypak Residential Low NOx Heater
0 - 5000 ft. Altitude
Digital Low NOx Models, copper tubing
(1) meets requirement for Low NOx air quality standard
Raypak 207 Digital Low NOx
199,500
Natural Gas
$1549
Raypak 267 Digital, Low NOx
266,000
Natural Gas
$1699
Raypak 337 Digital, Low NOx
332,500
Natural Gas
$1829
Raypak 407 Digital, Low NOx
399,000
Natural Gas
$1999
0 - 5000 ft. Altitude
Raypak Low NOx, commercial, ASME
(1) meets requirement for So. CA air quality standard
(2) meets requirement for installation in public pools
Commercial
Digital 207, Low NOx, ASME
199,500
Natural Gas
$1649
Digital 267, Low NOx, ASME
266,000
Natural Gas
$1818
Digital 337, Low NOx, ASME
332,500
Natural Gas
$1995
Digital 407, Low NOx, ASME
399,000
Natural Gas
$2189
0 - 5000 ft. Altitude
Digital Low NOx Cupro-Nickel Models
(1) meets requirement for So. CA air quality standard
(3) can be used with salt water chlorine systems
RayPak 207, Cupro-Ni
199,500
Natural Gas
$1836
RayPak 267, Cupro-Ni
266,000
Natural Gas
$1989
RayPak 337, Cupro-Ni
332,500
Natural Gas
$2192
RayPak 407, Cupro-Ni
399,000
Natural Gas
$2395
0 - 5000 ft. Altitude
Commercial, ASME, Cupro-Nickel, Low NOx
(1) meets requirement for So. CA air quality standard
(2) meets requirement for installation in public pools
(3) can be used with salt water chlorine systems
Commercial
Raypak 207 ASME Commercial Low NOx
199,500
Natural Gas
$1949
Raypak 267 ASME Commercial Low NOx
266,000
Natural Gas
$2099
Raypak 337 ASME Commercial Low NOx
332,500
Natural Gas
$2299
Raypak 407 ASME Commercial Low NOx
399,000
Natural Gas
$2499

RayPak Heater Accessories

RAYPAK HEATER PARTS

Part # 010329F
Part # 006736F
Part # 010253F
Part # 009492F
Part # 010232F
RayPak replacement Honeywell gas valve for 207 - 407 heaters
Natural gas
RayPak replacement Transformer kit 120/240 v for all heaters
RayPak PC boad controller kit for the 207 - 407 heaters 3-wire
RayPak cotrol panel swith decal membrane 185-405, 206-407
RayPak heater pilot kit 207 -407 heaters





RayPak outdoor High Wind Stack: High Wind Top Kits - In some areas where high winds are frequently experienced it may be necessary to install a Raypak High Wind Top. Installation of the High Wind Top will assist proper flueing of the heater and improve operation. High wind tops are available for all models xcept the Spartan 131, Premium 127 and 167.

The D-2 Power Vent is required for all indoor installation of the RayPak heaters. D-2 Power Vent is assembled as a category III mechanical draft venting system that operates under a positive static pressure and prevents excessive condensate production in the vent. All sizes are capable of relieving the flue gases up to a maximum of 100 equivalent feet of vent length. All models have a standard 4" diameter exhaust connection.

RayPak Heater Accessories

- D-2 Power Vent for 206/207 - 266/267 heaters Part # 009832

- D-2 Power Vent for 336/337 - 406/407 heaters Part # 009833


The Raypak D-2 Power Vent: Sometimes, equipment rooms or unusual venting configurations require the use of a power vent. Being the heater experts, we have the D2 Power Vent assembled in a category III mechanical draft venting system that operates under a positive static pressure and prevents excessive condensate production in the vent. All sizes are capable of relieving the flue gases up to a maximum of 100 equivalent feet of vent length. All models have a standard 4" diameter exhaust connection. Using the Raypak-supplied adjustable 90 degree elbow, the flue gases may be discharged in any direction (see the D-2 Power Vent manual for details). The D-2 Power Vent is also dual-voltage capable (120/240 volts) and engineered for long life and smooth operation.

RayPak Indoor / Outdoor Tops

Idoor Stack Tops:
Raypak Indoor Stack Top 206/207 Heaters part# 009838
Raypak Indoor Stack Top 266/267 Heaters part# 009839
Raypak Indoor Stack Top 336/337 Heaters part# 009840
Raypak Indoor Stack Top 406/407 Heaters part# 009838

Outdoor High Wind tops:
Raypak Outdoor High Wind Top 206/207 Heaters part# 009834
Raypak Outdoor High Wind Top 266/267 Heaters part# 009835
Raypak Outdoor High Wind Top 336/337 Heaters part# 009836
Raypak Outdoor High Wind Top 406/407 Heaters part# 009837

Product Reviews

Login or Register to write the first review.