|
Hayward
H-Series Low NOx Pool Heater
With
the state of-the-industry Finn Plate cupro-nickel heat exchanger
and patented rust-ressitant polymer headers, Hayward H-series
Low NOx pool heaters are the ideal choice for new salt-based
chlorine systems. Designed for superior reliability, durability
and long-life. Hayward H-series pool heater also features
dual 110/220 volt terminals and digital LED control panel.
Engineered with heat-trapping insulated Fire Tile Combustion
Chambers, you will be assured to receive maximum comfort from
every BTU.

| Model |
Pool
Heater Description |
BTU |
Gas
Type |
Discounted
Price |
|
|
Hayward
Low NOx H250 heater |
250,000
|
Natural
Gas |
$1389
$1249 |
| H250iDpL2 |
Hayward
Low NOx H250 heater
|
250,000
|
Propane |
$1495
$1299 |
| H350iDL2 |
Hayward
Low NOx H350 heater |
350,000
|
Natural
Gas |
$1595
$1429 |
| H350iDpL2 |
Hayward
Low NOx H350 heater |
350,000
|
Propane |
$1665
$1559 |
| H400iDL2 |
Hayward
Low NOx H400 heater |
400,000
|
Natural
Gas |
$1695
$1559 |
| H400iDpL2 |
Hayward
Low NOx H400 heater |
400,000
|
Propane |
$1765
$1695 |
Cupro-Nickel Heat Exchanger with every
Hayward Heater 
|
Works well with high water flow systems - withstands higher
water velocity |
Ideal for salt
water systems |
Corrosion resistant for longer life and chemical tolerance |
The new
Hayward
Low NOX Pool Heater
features a patent pending Finn Plate heat exchanger
for constant heat dispersment, state-of-the-art premix burners
for environmentally friendly Low NOx outputs, hot surface
ignition for reliable fire up, and an advanced L.E.D digital
control panel for simple programming of pool temperature.
The Hayward
Low NOX Pool Heater
also includes and induced draft system that constantly moves
air through the combustion chamber a a precise flow rate.
As a result, all outside weather variables that can affect
the heating performance, such as wind conditions, are eliminated
- without having to install a high wind stack.
NOTE:
The Hayward IDL2 pool heater meets the NOx Emission
standards set by the California South Coast Quality Air Management
Commission for 2001 and the Texas Natural Resource Conservation
Commission Code.
How
to Size a Hayward Pool Heater
Installation
and Operation Guide
IDL2
Low NOx Pool Heater Features:
New
Advanced Flame Sensor: an
integral safety feature in every Hayward IDL2 series
pool heater which ensures an automatic shutdown of
gas flow anytime a live flame cannot be verified by
sensor.
| New
Reliable, Durable Nitride Igniter: the
Hayward IDL2 pool heater comes with the industry's
first high-end, Silicon-Nitride (SiNi) ignitor.
Silicon-Nitride ignitor eliminates concerns about
condensation, chemicals, dirt or oily fingers
shortening ignitor life or causing ignitor failure.
With it's tungsten heating element sandwiched
between two layers of Silicon-Nitride insulators,
the new IDL2 ignitor's design is sturdier and
much more forgiving to mishandling. |
|
|
|
| New
circuit boards and codecs: the IDL2 pool heater
comes with three integrated but separate circuit
boards: Fuse board, Display Board and Ignition
Control Board. With advanced diagnostics and startup
Codecs the IDL2 has more intelligent monitoring
of the heater operation and status. The revisable
ribbon cables that can be plug either way ensure
that circuit boards are not damaged from improper
wiring. |
|
|
|
| Dual
Voltage Transformer and Boards: the
IDL2 pool heater is by far the easiest to install
on the market. All it takes to wire the IDL2 heater
to the correct voltage setting is to plug-in the
correct AC plug (120 volts or 240 volts) into
the Fuse Board's 4-pin female connector. The power
board circuit board is protected with replaceable
fuses which prevents costly transformer or circuit
board replacements. |
|
|
|
Optional
Pool Heater Accessories:
| Easy-to-read
Digital temperature read-outs, with the ability
to easily set the temperature and monitor system
diagnostics, to create the most enjoyable pool
environment possible. All H-series electronic
pool heaters including Low NoX pool heater come
with digital control panel. |
|
|
|
| Induced
draft systems constantly moves air through the
combustion chamber at a precise flow rate, eliminating
all outside weather variables that can affect
the heating performance, such as high wind conditions
- without a high wind stack. |
|
|
|
| Built
to withstand the harshest of conditions, the h-series
pool heater employ rust-resistant water path,
with injection molded polymer header and union
lock-nut assembly, provides for extended product
life and simple installation. 10
year warranty on Polymer Heads |
|
|
|
| Patent
pending heat exchanger design is the first of
it's kind in the pool business. The single header
design combined with our unique "V"
baffle allows for long life, fast heating and
virtually no condensation. |
|
|
|
| Like
all Hayward products, the H-Series pool heater
is designed to the most exacting standards of
any pool system. You will be equally impressed
with the appearance and user-friendliness as you
are with their performance. |
|
|
|
| Insulated
combustion chambers, including one inch thick
Fire Tile are featured in every model, and the
result is spectacular and consistent performance
day after day. Unlike older forms of insulation,
Fire Tile securely traps in the heat and does
not allow it to escape. |
|
|
|